Medida de nivel sin contacto – Radar & Ultrasónico

6, 10, 24 and 80 GHz Radar Level transmitters for every application

KROHNE introduces six new radar devices – three operate at 24 GHz and three more at 80 GHz – which complement the existing 6 GHz and 10 GHz devices. They will appeal to a wide range of industries from chemical and petrochemical to mining, minerals and metals processing and cover liquid and solid applications.

OPTIWAVE 1010 OPTIWAVE 5200 C/F OPTIWAVE 5400 C OPTIWAVE 7400 C OPTIWAVE 7500 C OPTIWAVE 3500 C OPTIWAVE 6400 C OPTIWAVE 6500 C OPTIWAVE 8300 Marine OPTISOUND 30x0
Measuring principle FMCW Radar
6 GHz
FMCW Radar
10 GHz
FMCW Radar
24-26 GHz
FMCW Radar
24-26 GHz
FMCW Radar
80 GHz
FMCW Radar
80 GHz
FMCW Radar
24-26 GHz
FMCW Radar
80 GHz
FMCW Radar
24-26 GHz
Ultra-
sonic
Measuring range
≤ 8 m;
≤ 26.2 ft
x x x x x x x x x x
Measuring range
≤ 15 m;
≤ 49.2 ft
x x x x x x x x x
Measuring range
≤ 30 m;
≤ 98.4 ft
x x x x x x x x
Measuring range
≤ 40 m;
≤ 131.2 ft
x x x x x x x
Measuring range
≤ 50 m;
≤ 164 ft
x x x x x x
Measuring range
≤ 100 m;
≤ 328.4 ft
x x x x x
Storage tanks x x x x x x x x x x
Still well/
reference chambers
x x x x x x x
Process tanks x x x x x x x
Complex process tanks
(e.g. with agitators)
x x x x
Bulk solids x x x
Pressure
≤ 2 barg;
≤ 29 psig
x x x x x x x x x x
Pressure
≤ 16 barg;
≤ 232 psig
x x x x x x x x x
Pressure
≤ 25 barg;
≤ 362.6 psig
x x x x x x x
Pressure
≤ 40 barg;
≤ 580 psig
x x x x x x
Pressure
≤ 100 barg;
≤ 1450 psig
x
Process connection temperature
≤ +80°C;
≤ +176°F
x x x x x x x x x x
Process connection temperature
≤ +130°C;
≤ +266°F
x x x x x x x x x
Process connection temperature
≤ +150°C;
≤ +302°F
x x x x x x x
Process connection temperature
≤ +200°C;
≤ +392°F
x x x
Process connection temperature
≤ +250°C;
≤ +482°F
x
2-wire-technology x x x x x x x x x x
4-wire-technology x
Profibus PA/FF x 2) 2) 2) 2) 2) 2)
Ex x x x x x x x x x x
SIL x 3) 3) 3) 3) 3) 3)
Marine approvals 2) 2) x
x suitable
1) marketed through our KROHNE Marine Sales office
2) Available by the 2nd quarter of 2018 at the latest
3) Developed acc. to SIL 2/3, IEC 61508 – 2010. The SIL approval is in the process of validation by TÜV Süd, Germany.